Description
Article description
Torque Measuring System consisting of:
- High precision ( shortbuilding)Torque transducer flange with with integrated amplifier
- Evaluation unit with integrated Stator antenna
- Documentation on USB-Stick
Measuring system
- torque range: 2 kN·m
- linearity deviation and hysterese torque (total system): 0.05 %
- standard Flange (see Catalog)
- special for test rig application
- repeatability < 0,03 %
- improved remanenz
- max Load (related to norminal Load): 400 %
- max breaking Load(related To norminal Load): 800 %
- max speed 15000 rpm
- strain gauge based
- signal bandwitdh : 1 kHz(-3dB)
- integrierted rotating amplifier
- inductive Transmission on basis of Sensortelemetry Technology
- PCM-technic, 16 Bit resolution
- integrated rotor induction loop
automatic temperature compensation
remaining max zero point drift(TK0): 0,05 %/10 centigrade - Signal frequency range: 1 kHz (- 3 dB)
- remote Calibration aktiv = 80 % of max. Load
- protection IP52
- without receiver and Pickup
- temperature range -10..+85° Centigrade
- with factory Calibration zertificat
Evaluation unit
Type XtreMA Torque
- housing: 120 x 70 x 30 mm (without ground plane)
- integrated Signal Pick Up (Stator antenna)
- Remote shunt calibration
- PCM-Technic
- samplerate = 6620 1/s
- bandwidth = 1 KHz
- resolution 16 for high precision applications
- protection IP42
- digital-analog-converter
- Output voltage 0..+/-10 V, 100 Ohm
- Frequency output 60 kHz+/-30 KHz, TTL 5 volts
- total channel count: 1
- D-Sub Connector
- Supply voltage 24V DC +/-10%
- temperature range: -10..+70° Centigrade
- digital-analoge-converter
- Linearity: < 0,005 %
- zeropointdrift: + / – 0,01 %/° Centigrade
Included in delivery
- High precision (shortbuilding)Torque transducer flange with with integrated amplifier
- Evaluation unit Typ XTREMA-Torque
- Calibration protocol and Documentation on USB-Stick
Not included in delivery
- Digital interface incl. conditioning software
(needed to condition the measuring amplifier)