Skip to main content

non-contact, high-precision, modular

MANNER Telemetry Components

Sensors

Record the variable to be measured and transmit this as a raw measured value to the measuring amplifier.

Measuring Amplifier

Prepare the signal for transmission. The signal is digitized and error compensated.

Transmission

Inductively, via a high-frequency electric field, using a rotor and stator antenna.

Evaluation Unit

Data reception by a stator antenna. Data is demodulated and checked.

Data Reception

Data transfer for recording or remote configuration of the measuring chain to a PC.

Sensors

We, the MANNER Sensortelemetrie GmbH, combine various sensors with our sensor telemetry system. This means that we select the suitable sensor for the variable to be measured together with the customer. Either this is done as a side order or as supply by us.

Our multifunctional systems can be adapted to almost any sensor. A selection of typical applied sensors is mentioned here as an example. This is not a complete list of available sensors.

  • Strain gauges in ¼-, ½-, and full bridge circuit (recording of strains, manufacture of measuring elements for recording axial force, bending moment, torque …)
  • Accelerometers
  • Pressure sensors
  • Temperature sensors (PT100, TC, others)
  • Inductive displacement sensors
  • Speed sensors
  • Bearing encoder
  • Angle encoder

Measuring Amplifier

SV-Flex – Sensor Signal Amplifier Type Samy Flex

For strain gage, PT100
Sensitivity: 0.02 mV/V to 11 mV/V
Bandwidth: 10 Hz to 10 kHz
Strain gage brigde supply: 3.3 V
Strain gage bridge resistance: 350 (120, 1000)

SV-Flex – Sensor Signal Amplifier Type Kalimero

For thermocouple (isolated or non-isolated), Pt100, strain gage
Measuring range up to 1000°C
Bandwidth: up to 500 Hz with 1 channel, up to 100 Hz with 16 channels

SV2a – Sensor Signal Amplifier Type 2a (with integrated Rotor Antenna)

For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV2b – Sensor Signal Amplifier Type 2b (with integrated Rotor Antenna)

End of shaft, Cartridge, Turbine, Integrated Rotor Coil
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV2bx – Sensor Signal Amplifier Type 2bx (with integrated Rotor Antenna)

End of shaft, Cartridge, Turbine, Integrated Rotor Coil
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV2c – Sensor Signal Amplifier Type 2c (with integrated Rotor Antenna)

End of shaft, Miniatur Cartridge, Turbine
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV2d – Sensor Signal Amplifier Type 2d (with integrated Rotor Antenna)

End of shaft, Miniatur Cartridge, Turbine
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV2La – Universal Shaft Transmitter with Sensor Signal Amplifier Type 2La

non dividable, 1 channel, with/without RMC, without rpm sensor
Beared wheel transmitter
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 10 kHz

SV2Lg – Universal Shaft Transmitter with Sensor Signal Amplifier Type 2Lg

dividable, 1 channel, with/without RMC, without rpm sensor
Beared wheel transmitter
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 10 kHz

SV3a – Sensor Signal Amplifier Type 3a

For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV3b – Sensor Signal Amplifier Type 3b

For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV3c – Sensor Signal Amplifier Type 3c

For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV4a – Sensor Signal Amplifier Type 4a

For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV4b – Sensor Signal Amplifier Type 4b

For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV5a – Sensor Signal Amplifier Type 5a

For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV5b – Sensor Signal Amplifier Type 5b

For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV5c – Sensor Signal Amplifier Type 5c

Miniature Patrone
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV5d – Sensor Signal Amplifier Type 5d

Super Miniature Patrone
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 1 kHz

SV7a – Miniatur Sensor Signal Amplifier Type 7a

Flatchip
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV7b – Super Miniatur Sensor Signal Amplifier Type 7b Micro

Flatchip
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 10 kHz

SV7ke – Miniatur Sensor Signal Amplifier Type 7ke

Flatchip with integrated Antenna (special for Chain Application)
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV8a – Waterproof Sensor Signal Amplifier Type 8a

Transmitter with Antenna
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

SV9 – Sensor Signal Amplifier Type 9

Transmitter with Antenna especially for Driveshaftes
For strain gage, PT100, thermocouple
Sensitivity: 0.02 mV/V to 20 mV/V
Bandwidth: 0 (10) Hz to 50 kHz

Evaluation Units

AW_DAnt – Evaluation Unit (integrated Pick Up)

1 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA, frequency, binary
RF power: 1 W, 3 W

OptiMA IP67 – Evaluation Unit

extraordinary transmission range up to 50 mm

1 to 2 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA, frequency, binary
RF power: 3 W

AW_M – Evaluation Unit

1 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA, frequency, binary
RF power: 1 W, 3 W

AW_P – Evaluation Unit

1 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA, frequency, binary, USB, CAN
RF power: 1 W, 3 W, 5W

MAW_F – Evaluation Unit Digital Receiver

1 to 64 Channel PCM Receiver
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz)
Output: 0 to ±10 V, (0 (4) to 20 mA option
Digital interface (option): USB, Ethernet (TCP/IP), EtherCAT

AW42TE – Evaluation Unit (42TE)

Multi Channel PCM Receiver 42 TE
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz option)
Output: 0 to ±10 V
Interfaces (option): USB

AW84TE – Evaluation Unit (84TE, 3HE)

Multi Channel PCM Receiver 84 TE
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz option)
Output: 0 to ±10 V
Interfaces (option): USB

AW84TE – Evaluation Unit (84TE, 6HE)

Multi Channel PCM Receiver 84TE HE6
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz option)
Output: 0 to ±10 V
Interfaces (option): USB

AW_ES_MGC – Evaluation MGC Plugin Unit

1 Channel MGC-Plugin Unit PCM Receiver
Bandwidth: 0 t 1 kHz
Output: 5 to 15 kHz
RF power: 3 W

AW_ES – Evaluation Unit

Multi Channel PCM Receiver ES
Bandwidth: 0 t 1 kHz (10 kHz, 50 kHz option)
Output: 0 to ±10 V
Interfaces (option): USB

Data Reception

MANNER offers its customers tailor-made software for their telemetry systems. This enables them to make the necessary settings themselves – conveniently via their PC.