Telemetry Kit 30-020 – OptiMA IP42

2.890,08 

Description

Article description

Torque Measuring System consisting of:

  • Sensor signal amplifier with integrated rotor antenna alignment for easy plug & play application
  • Rotor kit
  • evaluation unit with integrated stator antenna
  • Documentation

Measuring system

  • Measuring range (default): 1 mV/V
  • Signal resolution: 16 Bit
  • Linearity and hysteresis: <0.25%
  • Distance rotor to evaluation unit: 0.5 – 45 mm
  • PCM technique
  • Maintenance-free
  • Remote Shunt Calibration function with resistor

SV_4e

  • Miniature measurement amplifier with integrated rotor antenna alignment for easy plug & play application
  • Compact chip with solder pads
  • Geometry length = 39 mm, width: 9.6 mm, height 9 mm
  • weight: 7,2g
  • max. acceleration load: 20000 g (depending on mounting)
  • suitable for strain gauge, resistor 350,(120, 1000) Ohm, PT100
  • default conditioning strain gauge, measuring range 1 mV/V
  • PCM technology, resolution 16 bit for high precision applications
  • Digitization in rotor, integrated data backup
  • Sampling rate = 6620 1/s
  • bandwidth: 1 kHz
  • Improved zero and gain drift 0.01%/°C, linearity 0.05% typ.
  • Temperature range -25..+85° C
  • suitable for strain gauge, resistance 350,(120, 1000) Ohm, PT100
  • default conditioning strain gauge, measuring range 1 mV/V

Rotor antenna kit

  • Temperature range: -10 … +85°C
  • Protection class according to EN 60529: IP67 with potting kit (not included, see potting kit 30-100)

Evaluation unit
Sensor signal rotary transformer OptiMA IP42

  • with integrated Pick UP, cross polarized with large transmission range up to 45 mm with strain gauge resistance >=1000 Ohm)
  • housing 141 x 60 x 36 mm
  • remote calibration function, signal status display : LED
  • integrated generator to supply rotor electronics
  • option HF power: 3W
  • PCM technology
  • supply frequency 6,78 MHz
  • sampling rate = 3310 1/s
  • bandwidth = 1 KHz
  • resolution 16 bit for high precision applications
  • IP42
  • Digital to analog conversion
  • output voltage 0..+/-10 V, 100 Ohm
  • supply voltage 9..36 V
  • temperature range: -10..+70° C
  • Digital to analog conversion
  • Linearity: < 0,005 %,
  • zero drift: +/- 0.02%/°C

VKab_D_ana_Kal

  • Connector: D-SUB-9 socket
Included in delivery

  • Sensor signal amplifier SV_4e
  • Evaluation Unit OptiMA IP42
  • D-SUB-9 socket for systems with analog data output
  • Documentation on USB-Stick

Not included in delivery

  • Strain gauge sensor
  • Supplementary resistors
  • Digital interface incl. conditioning software
    (needed to condition the measuring amplifier)
  • Sealing Kit (to be ordered separately)